GE Bright speed
As good as new#New tube#Instock
Rs. 7900000
Configuration :
Model
: GE Bright speed
Make
: GE
Year
: 2010
Category
: CT Scan
MODEL Bright Speed 16 Type (CONFIGURATION) Multi-Slice # of slices (X-ray tube anode) 16 DICOM (GANTRY) As defined in DICOM Conformance Statement CT image storage SCU/SCP (Range of movement) Yes Modality worklist SCU (Range of movement) Yes Query/Retrieve SCU and SCP (Range of movement) Yes Storage commitment SCU (Range of movement) Yes Modality performed procedure step SCU (Range of movement)Yes IHE profiles supported (Range of movement) Yes TABLE FEATURES Range of movement Vertical, cm (Range of movement) 51.6-99 Longitudinal, cm (Range of movement) 100 Scanning range (Range of movement) 170 Max load capacity (accuracy, mm), without restrictions, kg (Range of movement) 180 (±0.25 mm), 205 (±1 mm) POWER NEEDED 460/480 VAC nominal, 50/60 Hz, 3-phase delta or wye SYSTEM INTEGRATION Auto bone removal (CLINICAL APPLICATIONS AND FUNCTIONALITY) Optional Body perfusion (CLINICAL APPLICATIONS AND FUNCTIONALITY) Optional Other (ROTORS) Cardiac, perfusion, lung analysis, CT colonography, Denta Scan, CT angiography IMAGE RECONSTRUCTION Cpu (NETWORK/DATABASE) Open architecture/ LINUX Scan fovs, cm (IMAGE PROCESSING) 25, 50 Reconstruction matrices (IMAGE RECONSTRUCTION) 512 x 512 Per slice, sec (Reconstruction time) Up to 16 frames/sec No. of online images (IMAGE STORAGE) 250,000 (512 x 512) Archive (IMAGE STORAGE) 2.3 GB MOD, DICOM 3.0 GANTRY Gantry angle deg (GANTRY) ±30 Gantry size, hxwxd,cm (GANTRY) 188.2 x 222.3 x 100.6 Gantry weight, kg (GANTRY) 1269 Gantry opening, cm (GANTRY) 70 Scan localizer (GANTRY) Laser RADIATION DOSE Dose modulation technique (X-ray tube anode) Volara DAS, OptiDose, color coding for kids, 3-D dose modulation, ECG dose modulation, beam tracking, short gantry geometry Pediatric specific dose control (RADIATION DOSE) Color coding for kids IMAGE PROCESSING (MAXIMUM DISPLAY) Standard or optional (IMAGE PROCESSING) Optional Recommended post-processing workstation (IMAGE PROCESSING) AW Remote access to clinical applications (IMAGE PROCESSING) Optional Dicom 3 D image export (IMAGE PROCESSING) Yes RECOMMENDED ROOM SIZE, m² (IMAGE PROCESSING) 28 minimum X-RAY TUBE Heat storage, MHU (X-RAY TUBE) 6.3 MHU Heat Dissipation rate, kHU/min (X-RAY TUBE) 840 Tube cooling (X-ray tube anode) Oil/air Tube focal spots, mm (X-RAY TUBE) 0.7 x 0.6, 0.9 x 0.7 Expected tube life, scan sec (& calendar) (X-RAY TUBE) See tube warranty Maximum ma (X-ray tube anode) 440 Maximum scan time at maximum ma, sec (X-ray tube anode) 20 GENERATOR kW output (GENERATOR) 53.2 Kvp range (GENERATOR) 80, 100, 120, 140 Ma range (IMAGING SYSTEM) 10 DETECTOR (SCATTERED LIGHT) Total detector width, z-axis, mm (DETECTOR) 20 Reconstructed slice width options, mm (GANTRY) 0.625,1.25,2.5, 3.75, 5, 7.5, 10 Standard Rotation times, sec, 360° (DETECTOR) 0.5, 0.6, 0.7, 0.8, 0.9, 1, 2, 3, 4 (VariSpeed provides 0.1 sec increments from 0.5 to 1 sec) OTHER ATTRIBUTES SmartmA-3-D dose modulation, color coding for kids, in-room start, remote tilt, rear gantry control, breathing lights with timer, MPR, AutoScan, AutoFilm, AutoVoice, AutoTransfer, AutoArchive, SmartPrep, ProtocolPro, ProView, ConnectPro, View/Edit Wizard,
CATEGORIES
CT Scan
CT Tube
MRI
Cathlab